Stelpro USA

It appears you’re in Canada. You’re currently viewing the American website. Note that currencies and availability on the American and Canadian websites differ.

Vous semblez provenir du Canada, mais vous êtes actuellement sur le site américain. Veuillez noter que les devises et la disponibilité des produits diffèrent d’un site à l’autre.

Stay on the American website
Rester sur le site américain

Visit the Canadian website
Aller sur le site canadien

All Systems Operational

Since Tuesday, 02/23/2021 04:00
Eastern Time Zone

  • logo Flextherm

Explosion-Proof Sloped Top Convector Heater

Your ally in hazardous locations

SEC New

Stelpro’s X-PRO series explosion-proof convector heater is designed for hazardous locations. Available in a range of wattages (from 0.4 kW to 10 kW) and voltages (120 V to 600 V) along with many controls and options available, this heavy-duty unit is designed to meet your most demanding needs.

Product images

  • SEC_ANGLE_1000x600px
  • SEC_FRONT_1000x600px
  • SEC_SIDE_1000x600px

Advantages

  • Quick and easy installationWall mounting bracket compatible with select competitor models included
  • Robust, exclusive heating elementEngineered for optimal, even heat distribution
  • Precision built-in thermostatConsistent and reliable temperature control
  • Extensive model selectionMultiple power levels, voltages, and phases available to suit any application
  • Smart sloped top designDeterrent to use as a shelf or seating surface

COLOR

  • Standard: red

FINISH

  • Standard: epoxy/polyester powder paint

VOLTAGE

  • 120 V, 208 V, 240 V, 277 V, 347 V, 480 V, 600 V, 1 or 3-phase

MANUFACTURING

  • Sloped top. 14-gauge galvanized steel back panel
  • 14-gauge carbon steel front and side panels with epoxy/polyester powder-coating.
  • Low temperature convection
  • Linear high-limit temperature control with automatic reset
  • Sealed junction box

ELEMENTS

  • Incoloy® 800 tubular heating element with radial-embossed aluminum fins

STANDARDS

  • CSA C22.2 No. 30, No. 60079-0, No. 60079-1, No. 46, No. 60529, No. 94.2
  • ANSI/UL 823, 60079-0, 60079-1
  • ANSI/IEC 60529
  • UL 50E

CLASSIFICATION

  • North American Hazardous Location:
    • Class I, Division 1 and 2, Groups B, C and D (T2B or T3A)
    • Class I, Zone 1 and 2, Ex db, Groups IIA, IIB+H2, Gb
    • Class I, Zone 1 and 2, AEx db, Groups IIA, IIB+H2, Gb
    • Ta = −50 °C to +40 °C, IP66, Type 4, (T2 or T3)

TEMPERATURE CODE

  • Division System: T2B 260 °C (500 °F) or T3A 180 °C (356 °F)
  • Zone System: T2 300 °C (572 °F) or T3 200 °C (392 °F)

INGRESS PROTECTION

  • IP66 and Type 4

CONTROL

  • Built-in thermostat or wall thermostat available

INSTALLATION

  • Built-in wall bracket
  • Minimum mounting distances of 8 in. (20 cm) above the floor and 18 in. (45 cm) from the ceiling

WARRANTY

  • One year